


default search action
10. IWDM 2010: Girona, Catalonia, Spain
- Joan Martí, Arnau Oliver, Jordi Freixenet, Robert Marti:
Digital Mammography, 10th International Workshop, IWDM 2010, Girona, Catalonia, Spain, June 16-18, 2010. Proceedings. Lecture Notes in Computer Science 6136, Springer 2010, ISBN 978-3-642-13665-8
CAD
- Paul M. Taylor
, Henry W. W. Potts, Louise Wilkinson, Rosalind M. Given-Wilson:
Impact of CAD with Full Field Digital Mammography on Workflow and Cost. 1-8 - Neha Bhooshan, Maryellen L. Giger
, Karen Drukker
, Yading Yuan, Hui Li, Stephanie McCann, Gillian Newstead, Charlene A. Sennett:
Performance of Triple-Modality CADx on Breast Cancer Diagnostic Classification. 9-14 - Laurence Vancamberg, Anis Sahbani
, Serge Muller, Guillaume Morel:
Needle Path Planning Method for Digital Breast Tomosynthesis Biopsy Based on Probabilistic Techniques. 15-22 - Thomy Mertzanidou
, John H. Hipwell, Manuel Jorge Cardoso
, Christine Tanner, Sébastien Ourselin
, David J. Hawkes:
X-ray Mammography - MRI Registration Using a Volume-Preserving Affine Transformation and an EM-MRF for Breast Tissue Classification. 23-30
Image Processing and Analysis I
- Fabian Zöhrer, Markus Thorsten Harz, Anke Bödicker, Heike Seyffarth, Kathy J. Schilling, László K. Tabár, Horst K. Hahn:
Interactive Multi-scale Contrast Enhancement of Previously Processed Digital Mammograms. 31-38 - Joan Massich, Fabrice Mériaudeau, Elsa Pérez, Robert Marti
, Arnau Oliver
, Joan Martí:
Lesion Segmentation in Breast Sonography. 39-45 - Jun Zheng, Olac Fuentes, Ming-Ying Leung
, Elais Jackson:
Mammogram Compression Using Super-Resolution. 46-53 - J. Michael O'Connor, Mini Das, Clay Didier, Mufeed Mah'd, Stephen J. Glick:
Development of an Ensemble of Digital Breast Object Models. 54-61 - Predrag R. Bakic
, Peter Ringer, Johnny Kuo, Susan Ng
, Andrew D. A. Maidment
:
Analysis of Geometric Accuracy in Digital Breast Tomosynthesis Reconstruction. 62-69
Breast Imaging Physics
- Paola Baldelli, James B. McCullagh, Niall Phelan, Fidelma Flanagan:
Results of Comprehensive Dose Survey for Mammography. 70-77 - Mary Yip, Federica Zanca
, Alistair Mackenzie
, Adam Workman, Kenneth C. Young, David R. Dance, Hilde Bosmans
, Emma Lewis, Kevin Wells:
Validation of a Simulated Dose Reduction Methodology Using Digital Mammography CDMAM Images and Mastectomy Images. 78-85 - James B. McCullagh, Paola Baldelli, Niall Phelan:
Measured Dose versus Organ Dose Performance in Digital Mammography Systems. 86-91 - Razvan Iordache, Maélène Lohezic, Giovanni Palma, Sylvie Puong, Serge Muller:
Noise Reduction in Dual-Energy Contrast Enhanced Digital Breast Tomosynthesis Using Regularization. 92-99 - Kristin Pedersen, Ingrid D. Landmark, Kirsti Bredholt, Ingrid H. R. Hauge, Hilde M. Olerud:
Phantom Dose Levels Found at Annual Physics Surveys in a National Mammography Screening Program: Comparison of Doses from Analog and Digital Equipment and from Digital Equipment at Different Points in Time. 100-105
Poster Session 1
- Xinying Wang, James G. Mainprize
, Gang Wu, Martin J. Yaffe:
Task-Based Evaluation of Image Quality of Filtered Back Projection for Breast Tomosynthesis. 106-113 - Emily F. Conant, Diane Li, Sara Gavenonis, Predrag R. Bakic
, Ann-Katherine Carton, Cuiping Zhang, Andrew D. A. Maidment
, Despina Kontos:
A Comparative Study of the Inter-reader Variability of Breast Percent Density Estimation in Digital Mammography: Potential Effect of Reader's Training and Clinical Experience. 114-120 - Horst K. Hahn, Markus Thorsten Harz, Heike Seyffarth, Fabian Zöhrer, Tobias Böhler, Konstantinos Filippatos, Lei Wang, André Homeyer
, Felix Ritter, Hendrik Laue, Matthias Günther, Thorsten Twellmann, László K. Tabár, Ulrich Bick
, Kathy J. Schilling:
Concepts for Efficient and Reliable Multi-modal Breast Image Reading. 121-128 - Paul Taylor:
Modeling the Impact of CAD on the Outcomes of the UK Breast Screening Programme. 129-136 - Satoru Matsuo, Hiroshi Fujita, Junji Morishita, Tetsuro Katafuchi:
Introducing a Novel Image Quality Measure for Digital Phase-Contrast-Image Evaluation. 137-144 - Michael Berks, Christopher J. Taylor
, Rumana Rahim, Caroline R. M. Boggis, Susan M. Astley:
Modelling Structural Deformations in Mammographic Tissue Using the Dual-Tree Complex Wavelet. 145-152 - Zezhi Chen, Michael Berks, Susan M. Astley, Christopher J. Taylor
:
Classification of Linear Structures in Mammograms Using Random Forests. 153-160 - Richard Lederman, Isaac Leichter, Eli Ratner, Menahem Abramov, Alexandra Manevitch, Jonathan Stoeckel:
Should CAD Be Used as a Second Reader? - Exploring Two Alternative Reading Modes for CAD in Screening Mammography. 161-167 - Camilla Jeffries-Chung, Jennifer Diffey, Michael Berks, Joanna Morrison, Rosanne Verow, Julie Morris, Mary Wilson, Caroline R. M. Boggis, Nicky B. Barr, Anthony Maxwell
, Alan Hufton, Susan M. Astley:
Automated Assessment of Area of Dense Tissue in the Breast: A Comparison with Human Estimation. 168-174 - Reyer Zwiggelaar:
Local Greylevel Appearance Histogram Based Texture Segmentation. 175-182 - Michiel Kallenberg
, Nico Karssemeijer:
Comparison of Tilt Correction Methods in Full Field Digital Mammograms. 191-196 - Christopher E. Tromans, Jennifer Diffey, Mary Cocker, Michael Brady:
Optimising Beam Quality Selection in Mammographic Acquisition Using the Standard Attenuation Rate. 197-204 - Christopher E. Tromans, Jennifer Diffey, Michael Brady:
Investigating the Replacement of the Physical Anti-scatter Grid with Digital Image Processing. 205-212 - Yoshifumi Kuroki, Katsuhiro Nasu, Seiko Kuroki, Ryuzo Sekiguchi, Shigeru Nawano, Mitsuo Satake:
Diffusion-Weighted Imaging (DWI) for Breast Cancers; Challenging to Diagnose Ductal Carcinoma in Situ (DCIS) and Invasive Lobular Carcinoma (ILC). 213-218 - Dirk A. N. Vandenbroucke, Paul J. R. Leblans:
CR Mammography: Image Quality Measurement and Model Calculation for Needle vs. Powder Imaging Plate. 219-226 - Hilde Bosmans
, Jürgen Jacobs, Eman Shaheen
, Federica Zanca
, Lesley Cockmartin, Kristina Bliznakova
, Kim Lemmens, Sabrina Vollmar, Willi A. Kalender, Nicholas Marshall
:
Performance Assessment of Breast Tomosynthesis Systems: Concepts for Two Types of Phantoms. 227-234 - Eman Shaheen
, Chantal Van Ongeval
, Lesley Cockmartin, Federica Zanca
, Nicholas Marshall
, Jürgen Jacobs, Hilde Bosmans
:
Realistic Simulation of Microcalcifications in Breast Tomosynthesis. 235-242 - Gang Wu, James G. Mainprize
, Martin J. Yaffe:
Breast Tomosynthesis Reconstruction Using a Grid of Blobs with Projection Matrices. 243-250 - Arnau Oliver
, Albert Torrent
, Meritxell Tortajada, Xavier Lladó
, Marta Peracaula
, Lidia Tortajada, Melcior Sentís
, Jordi Freixenet
:
A Boosting Based Approach for Automatic Micro-calcification Detection. 251-258 - Noelia Vállez
, Gloria Bueno García
, Oscar Déniz
, Pablo Esteve, Miguel A. Rienda, Carlos Pastor:
Automatic Breast Tissue Classification Based on BIRADS Categories. 259-266 - Hui Li, Maryellen L. Giger
, Olufunmilayo I. Olopade, Li Lan:
Validation of Mammographic Texture Analysis for Assessment of Breast Cancer Risk. 267-271 - Inna Stainvas
, Jonathan Stoeckel, Eli Ratner, Menachem Abramov, Richard Lederman:
Towards Learning Spiculation Score of the Masses in Mammography Images. 272-279 - László K. Tabár, Alfredo S. Niño, Eric Schreiber, Richard Ellis, Cynthia Goralnik, Steven Scislaw, Raja Cheruvu, Deepa Masrani, Daoxian Zhang, Steve Muller, Patrick Heffernan:
Three Digital Mammography Display Configurations: Observer Performance in a Pilot ROC Study. 280-287 - Nachiko Uchiyama, Jonathan Stoeckel, Kyoichi Otsuka, Seiko Kuroki, Yukio Muramatsu, Noriyuki Moriyama:
How Can Image Quality Affect the Detection Performance of Breast CAD (Computer Aided Detection) in FFDM (Full Field Digital Mammography)? - A Comparative Study with Two Different FFDM Systems-. 288-295 - Weiwei Zhang, Michael Brady:
Feature Point Detection for Non-rigid Registration of Digital Breast Tomosynthesis Images. 296-303 - Pedro Collado-Chamorro, Camilo Sanz-Freire, José Gómez-Amez, Alejandro Vázquez-Galiñanes, Natalia Lopo-Casqueiro, Maria González-De La Puente:
Contrast Detail Curves on Digital Mammography: Performance Comparison of Raw and Filtered Images. 304-311 - Elizabeth A. Krupinski:
Reader Fatigue Interpreting Mammograms. 312-318 - Alistair Mackenzie
, Adam Workman, David R. Dance, Mary Yip, Kevin Wells, Kenneth C. Young:
Adapting Clinical Images to Appear with Different Noise and Sharpness to Model a Different Detector. 319-326
Physics Models
- Ingrid S. Reiser, Robert M. Nishikawa
:
Human Observer Performance in a Single Slice or a Volume: Effect of Background Correlation. 327-333 - Margarita Chevalier
, Lorena Chanes
, Eduardo Guibelalde
, María-Ester Brandan, Tatiana Alieva:
Influence of Geometrical Factors on Phase Contrast Fiber Images. 334-341 - Ralph Highnam, Michael Brady, Martin J. Yaffe, Nico Karssemeijer, Jennifer A. Harvey:
Robust Breast Composition Measurement - VolparaTM. 342-349
Clinical Experiences
- Nicholas Marshall
, Jürgen Jacobs, Lesley Cockmartin, Hilde Bosmans
:
Technical Evaluation of a Digital Breast Tomosynthesis System. 350-356 - Yan Chen, Alastair G. Gale:
Mammographic Interpretation Training: How Could Low Cost Display Devices Help? 357-364 - Jennifer M. Oduko, Kenneth C. Young, Anna Burch:
A Survey of Patient Doses from Digital Mammography Systems in the UK in 2007 to 2009. 365-370 - Koen Michielsen
, Jürgen Jacobs, Nicholas Marshall
, Hilde Bosmans
:
Analysis of Mammography Quality Control Results: Evidence for a Change in Test Frequency? 371-377 - Despina Kontos, Predrag R. Bakic
, Raymond Joseph Acciavatti
, Emily F. Conant, Andrew D. A. Maidment
:
A Comparative Study of Volumetric and Area-Based Breast Density Estimation in Digital Mammography: Results from a Screening Population. 378-385
Breast Density
- Jennifer Diffey, Joanna Morrison, Michael Berks, Joanne Greene, Julie Morris, Anthony Maxwell
, Caroline R. M. Boggis, Alan Hufton, Susan M. Astley:
Volumetric Breast Density and Breast Cancer Risk Factors in a Screening Population. 386-393 - Mona Jeffreys
, Ruth Warren, Ralph Highnam, George Davey Smith
:
Determinants and Consequences of Change in Breast Density. 394-401 - Serghei Malkov
, Lin Ma, Karla Kerlikowske, Jeff Wang, Steve Cummings, John Shepherd:
Comparison of Subregional Breast Density with Whole Breast Density. 402-407 - Mona Jeffreys
, Jennifer A. Harvey, Ralph Highnam:
Comparing a New Volumetric Breast Density Method (VolparaTM) to Cumulus. 408-413 - Anisha Sukha, Michael Berks, Julie Morris, Caroline R. M. Boggis, Mary Wilson, Nicky B. Barr, Susan M. Astley:
Visual Assessment of Density in Digital Mammograms. 414-420
Digital Breast Tomosynthesis
- Willi A. Kalender:
Concepts for High-Resolution CT of the Breast. 421-427 - Steve Naday, Edward F. Bullard, Spencer Gunn, James E. Brodrick, Eoin O. O'Tuairisg, Alan McArthur, Hamdan Amin, Mark B. Williams, Patricia Goodale Judy, Anastasios Konstantinidis:
Optimised Breast Tomosynthesis with a Novel CMOS Flat Panel Detector. 428-435 - Raymond Joseph Acciavatti
, Andrew D. A. Maidment
:
Calculation of OTF, NPS, and DQE for Oblique X-Ray Incidence on Turbid Granular Phosphors. 436-443 - Mark B. Williams, Patricia Goodale Judy, Zongyi Gong, Audrey E. Graham, Stan Majewski, Spencer Gunn:
Scanner for Integrated X-Ray Breast Tomosynthesis and Molecular Breast Imaging Tomosynthesis. 444-451 - Predrag R. Bakic
, Beverly A. Lau, Ann-Katherine Carton, Ingrid S. Reiser, Andrew D. A. Maidment
, Robert M. Nishikawa
:
An Anthropomorphic Software Breast Phantom for Tomosynthesis Simulation: Power Spectrum Analysis of Phantom Projections. 452-458
Poster Session 2
- Nadia Oberhofer, Alessandro Fracchetti, Elvina Nassivera, Aldo Valentini, Ehrenfried Moroder:
Comparison of Two Novel FFDM Systems with Different a-Se Detector Technology: Physical Characterization and Phantom Contrast Detail Evaluation in Clinical Conditions. 459-466 - Olivier Alonzo-Proulx, James G. Mainprize
, Nathan J. Packard, John M. Boone, Adil Al-Mayah, Kristy K. Brock, Martin J. Yaffe:
Development of a Peripheral Thickness Estimation Method for Volumetric Breast Density Measurements in Mammography Using a 3D Finite Element Breast Model. 467-473 - Isaac Leichter, Zahava Gallimidi, Asnat Heyman-Reiss, Nicolas Merlet, Eli Ratner, Menachem Abramov, Inna Stainvas
, Richard Lederman:
Is CAD Able to Assist in the Detection of Subtle Breast Findings - Lobular Cancers, and T1a/T1b Masses in Dense Breasts? 474-480 - Carolina Wessel, Julia A. Schnabel
, Michael Brady:
Towards More Realistic Biomechanical Modelling of Tumours under Mammographic Compressions. 481-489 - Paul Taylor, Mark Hartswood, Lilian Blot, Rob Procter, Stuart Anderson
:
Scoring Systems in Computer-Based Training for Digital Mammography. 490-496 - Guido van Schie, Karin Leifland, Matthew Wallis, Elin Moa, Magnus Hemmendorff, Nico Karssemeijer:
The Effect of Slab Size on Mass Detection Performance of a Screen-Film CAD System in Reconstructed Tomosynthesis Volumes. 497-504 - Michael Berks, Christopher J. Taylor
, Rumana Rahim, David Barbosa da Silva, Caroline R. M. Boggis, Susan M. Astley:
Synthesising Malignant Breast Masses in Normal Mammograms. 505-512 - Nicola Barr, Caroline R. M. Boggis, Nicky B. Barr, Mary Wilson, Julie Morris, Michael Berks, Susan M. Astley:
Comparison of Microcalcification Detection Rates and Recall Rates in Digital and Analogue Mammography. 513-517 - Jürgen Jacobs, Nicholas Marshall
, Lesley Cockmartin, Ehsan Samei
, Hilde Bosmans
:
Constancy Checking of Digital Breast Tomosynthesis Systems. 518-525 - Wenda He, Erika R. E. Denton, Reyer Zwiggelaar:
Mammographic Image Segmentation and Risk Classification Using a Novel Texture Signature Based Methodology. 526-533 - Robert M. Nishikawa
, Lorenzo L. Pesce
:
Stratified Sampling for Case Selection Criteria for Evaluating CAD. 534-539 - Christine Tanner, John H. Hipwell, David J. Hawkes, Gábor Székely:
Breast Shapes on Real and Simulated Mammograms. 540-547 - Anna K. Jerebko, Markus Kowarschik, Thomas Mertelmeier:
Regularization Parameter Selection in Maximum a Posteriori Iterative Reconstruction for Digital Breast Tomosynthesis. 548-555 - Steven Raeymaeckers
, Nico Buls, Gert Van Gompel, Cathérine Breucq, Johan de Mey:
Image Quality Phantom in Close Compliance with the ICRU-44 Breast Tissue Substitute Standard and Realistic Background Noise Pattern for Digital Breast Tomosynthesis. 556-560 - Christopher E. Tromans, Michael Brady:
The Standard Attenuation Rate for Quantitative Mammography. 561-568 - Christian Moll, Andreas Jahnen
, Alex Meyer, Martine Grelot, Johannes Hermen, Carlo Back, Marie-Christine Wagnon, Norbert Rösch:
National Software Supported Quality Assurance Program in Digital Mammography: Experiences and Challenges. 569-575 - Rosanne Verow, Michael Berks, Jennifer Diffey, Camilla Chung, Joanna Morrison, Mary Wilson, Caroline R. M. Boggis, Nicky B. Barr, Julie Morris, Alan Hufton, Susan M. Astley:
Inter and Intra Observer Variability in a Semi-automatic Method for Measuring Volumetric Breast Density. 576-582 - Maki Yamada, Yuri Kato, Naotoshi Fujita, Yoshie Kodera:
Optimization of the Exposure Parameters with Signal-to-Noise Ratios Considering Human Visual Characteristics in Digital Mammography. 583-590 - John M. Boone, Nathan J. Packard, Craig K. Abbey:
Ideal Observer Comparison between Tomographic and Projection x-Ray Images of the Breast. 591-597 - Yue-Houng Hu, Michael Masiar, Wei Zhao:
Breast Structural Noise in Digital Breast Tomosynthesis and Its Dependence on Reconstruction Methods. 598-605 - Vjacheslav Gorshkov, Nadezhda Rozhkova, Sergey Prokopenko:
Dual-Energy Dividing Mammography. 606-613 - Antonio García-Manso
, Carlos J. García Orellana
, Ramón Gallardo Caballero, Horacio M. González Velasco
, Miguel Macías Macías
:
Effect of BI-RADS Assessment in Improving CAD of Masses. 614-621 - Ricardo Tortosa, Juan Ignacio Villaescusa
, Miguel Ramos
, Gumersindo Verdú:
Analysis of the Benefit/Risk Ratio Obtained in the Valencian Breast Early Detection Program During 2007 and 2008. 622-627 - Oliver Díaz
, Mary Yip, Jorge Cabello, David R. Dance, Kenneth C. Young, Kevin Wells:
Monte Carlo Simulation of Scatter Field for Calculation of Contrast of Discs in Synthetic CDMAM Images. 628-635 - Gobert N. Lee
, Toshiaki Okada, Daisuke Fukuoka, Chisako Muramatsu, Takeshi Hara, Takako Morita, Etsuo Takada, Tokiko Endo, Hiroshi Fujita:
Classifying Breast Masses in Volumetric Whole Breast Ultrasound Data: A 2.5-Dimensional Approach. 636-642 - Ruben E. van Engen, Kenneth C. Young, Hilde Bosmans
, Barbara Lazzari, Stephan Schopphoven, Patrice Heid, Martin Thijssen:
A supplement to the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis. 643-650 - Baorui Ren, Andrew P. Smith, Julian Marshall:
Investigation of Practical Scoring Methods for Breast Density. 651-658 - Rafael Salvador, Rafael Salvador-Izquierdo, Leonardo Romero, Xavier Salvador-Izquierdo, Manuel Salvador:
Performance of the New Double Layer Amorphous Selenium Detector for Digital Mammography Compared to the FDA Approved CR System for Digital Mammography. 659-663
Image Processing and Analysis II
- Neil Mac Parthaláin
, Reyer Zwiggelaar:
Machine Learning Techniques and Mammographic Risk Assessment. 664-672 - Fabián R. Narváez
, Gloria Díaz
, Eduardo Romero:
Automatic BI-RADS Description of Mammographic Masses. 673-681 - Candy P. S. Ho, Christopher E. Tromans, Julia A. Schnabel
, Michael Brady:
A Clustering Method for the Extraction of Microcalcifications Using Epipolar Curves in Digital Breast Tomosynthesis. 682-688
Lesion Detection
- Federica Zanca
, Guozhi Zhang, Nicholas Marshall
, Eman Shaheen
, Elena Salvagnini, Guy Marchal, Hilde Bosmans
:
Software Framework for Simulating Clusters of Microcalcifications in Digital Mammography. 689-696 - Mini Das, Howard C. Gifford
, J. Michael O'Connor, Stephen J. Glick:
Improved Microcalcification Detection for Breast Tomosynthesis Using a Penalized-Maximum-Likelihood Reconstruction Method. 697-703 - Candy P. S. Ho, Christopher E. Tromans, Julia A. Schnabel
, Michael Brady:
Microcalcification Detection in Digital Breast Tomosynthesis Using an Epipolar Curve Approach. 704-711 - Giovanni Palma, Isabelle Bloch, Serge Muller:
Spiculated Lesions and Architectural Distortions Detection in Digital Breast Tomosynthesis Datasets. 712-719 - Melissa L. Hill
, James G. Mainprize
, Martin J. Yaffe:
An Observer Model for Lesion Detectability in Contrast-Enhanced Digital Mammography. 720-727
Registration
- Lianghao Han
, John H. Hipwell, Zeike A. Taylor
, Christine Tanner, Sébastien Ourselin
, David J. Hawkes:
Fast Deformation Simulation of Breasts Using GPU-Based Dynamic Explicit Finite Element Method. 728-735 - Angela W. C. Lee, Julia A. Schnabel
, Vijay Rajagopal
, Poul M. F. Nielsen
, Martyn P. Nash
:
Breast Image Registration by Combining Finite Elements and Free-Form Deformations. 736-743 - Andrew Melbourne, John H. Hipwell, David J. Hawkes:
The Effect of Motion Correction on Pharmacokinetic Parameter Estimation. 744-751 - Fei Ma, Mariusz Bajger
, Simon Williams, Murk J. Bottema:
Improved Detection of Cancer in Screening Mammograms by Temporal Comparison. 752-759 - Guang Yang
, John H. Hipwell, Matthew J. Clarkson
, Christine Tanner, Thomy Mertzanidou
, Spencer Gunn, Sébastien Ourselin
, David J. Hawkes, Simon R. Arridge
:
Combined Reconstruction and Registration of Digital Breast Tomosynthesis. 760-768

manage site settings
To protect your privacy, all features that rely on external API calls from your browser are turned off by default. You need to opt-in for them to become active. All settings here will be stored as cookies with your web browser. For more information see our F.A.Q.